Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Jilin University(Medicine Edition) ; (6): 958-962, 2016.
Article in Chinese | WPRIM | ID: wpr-504794

ABSTRACT

Objective:To investigate the relationship between the gene polymorphism cluster of differentiation 14 (CD14)-159C/T (rs2569190),and interleukin-8 (IL-8)-251A/ T (rs4073)and the susceptibility of necrotizing enterocolitis (NEC),to clarify the influencing factors of susceptibility of NEC and to provide genetics theory basis for the research on the pathogenesis of NEC. Methods:Total 28 newborns with NEC and 41 newborns without NEC were selected.The amplification of peripheral blood DNA was conducted by PCR.The genotypic and allelic frequencies of CD14-159C/T and IL-8-251A/T of the patients were detected by Sanger DNA sequencing method. The relationship between them and the susceptibility of NEC was studied.Results:The distribution of genotypic frequencies of CD14-159C/T and IL-8-251A/T was consistent with Hardy-Weinberg equilibrium (P >0.05).There were no significant differences of the allelic and genotypic frequencies of CD14-159C/T,or genotypic frequencies of IL-8-251A/T between two groups (P >0.05).While in NEC group,the T allelic frequency of IL-8-251A/T site was higher than that in control group (χ2 = 4.184, P = 0.041, OR = 2.14, 95% CI: 1.03 - 4.46 ). Conclusion:The polymorphism of CD14-159C/T is irrelevant to the pathogeny of NEC,but T allelic frequency of IL-8-251A/T site might be related to the susceptibility of NEC.So T allele in IL-8-251A/T may be one of the danger factors of NEC.

2.
China Pharmacy ; (12): 2109-2110,2111, 2016.
Article in Chinese | WPRIM | ID: wpr-605666

ABSTRACT

OBJETCTIVE:To establish a method for the content determination of ethacridine lactate in Compound ethacridine ointment. METHODS:HPLC was performed on the column of Agilent ZORBAX SB-C18 with mobile phase of 0.1% Octanesulfon-ic acid sodium solution-acetonitrile(70∶30,V/V)at a flow rate of 1.0 ml/min,the detection wavelength was 270 nm,the column temperature was 30℃,and the injection volume was 10 μl. RESULTS:The linear range of ethacridine lactate was 10.002-50.010μg/ml(r=0.999 9);RSDs of precision,stability and reproducibility tests were less than 1%;recovery was 98.96%-100.36%(RSD=0.49%,n=9). CONCLUSIONS:The method is simple,accurate and reproducible,and can be used for content determina-tion of ethacridine lactate in Compound ethacridine ointment.

SELECTION OF CITATIONS
SEARCH DETAIL